ALARM TYPES התראות ארון ומשמעותן

ALARM TYPES
Problem Key
Activated when a key is removed from the KeyWatcher without a valid user code request. This can also be
triggered if the Smart Key is not being recognized by the system because it is not making contact inside the
location. See the maintenance section for more information.
Invalid Problem Key
Activated when an invalid key is removed from the KeyWatcher without a valid user code canceling the Invalid
key alarm. This can also be triggered if the Smart Key is not being recognized by the system because it is not
making contact inside the location. See the maintenance section for more information.
Key Not Taken
Activated when a user requests a key, but does not remove it from the KeyWatcher.
Invalid Key Return
Activated if a key that is not added to the system is returned. Please note that the invalid key return will sound an
alarm, but will NOT trigger the relay alarm output. See the Add Key section for information about adding keys.
Illegal Entry
Activated when the KeyWatcher’s door is opened without a valid user code being entered. This alarm will only be
triggered when the door sensor is Enabled. (see page 21)
Door Left Open
Activated when the door is left open after the removal or return of a key. This alarm will only be triggered when
the door sensor is Enabled. (see page 21)
AC Power Loss
Activated if the KeyWatcher loses AC power. This alarm is automatically canceled by the system when AC power
is restored.
Overdue Key
Activated if a key is not returned to the KeyWatcher prior to the programmed restriction time. If the alarm is
cancelled and the key is still not returned within 24 hours from the original overdue time, it will activate the alarm
again.
Ram Battery
Activated when the internal Ram Battery on the CPU board has failed the ram battery test. If this alarm is
triggered, verify that the Ram Battery Jumper is connected properly and reset the KeyWatcher. If the alarm keeps
reoccurring, the ram battery may need to be replaced. This alarm is cancelled automatically by the system when the
Ram Battery problem is corrected.
Printer
Activated when the printer has stopped printing information. If this alarm is triggered, verify that the printer is ONLINE,
the printer is not out of paper, the cable is connected properly from the KeyWatcher to the printer and it is
the correct cable.
Box Power loss
Activated when the AC power has been lost on a specific box when AC detect is enabled. This alarm is
automatically canceled by the system when AC power is restored to the box.
Shorted Key Return
Indicates that a shorted key (BAD KEY) has been returned to the system. Please note that the shorted key return
will sound an alarm but will NOT trigger relay the alarm output.
Illegal Return
Activated when a key has been returned to an incorrect location on a Non-Random (optional) system.
Box Battery Err
Activated when the box has failed the battery backup test. If this alarm is triggered, cancel the alarm. If the alarm
keeps reoccurring, the battery may need to be replaced in that box. This alarm is automatically canceled by the system
when the box battery problem is corrected.
Archive Warning
Activated when the transactions in the KeyWatcher have not been collected by the software. This alarm is automatically
canceled by the system when transactions are gathered by the software or the Archive Warning feature is
disabled.
Illegal Access
Activated when 3 consecutive unsuccessful attempts are made at entering a user code. This alarm will only be
triggered if the Access Enable feature is Enabled.(see page 22).
Cold Boot
Activated when the KeyWatcher has been completely reset. This can occur if the ERASE DATABASE feature has
been performed or the system was powered down, the Ram Battery Jumper removed and the system powered up.
Box Battery Low
Activated when AC power has been lost and the backup battery is at a low voltage. Restore AC power and allow
the battery to charge. If the alarm keeps reoccurring, the battery may need to be replaced in that box. This alarm is
automatically canceled by the system when the box battery low problem is corrected.
Comm Lost
Activated when communication to a box has been lost. If this alarm is triggered, verify that the cable to the box
board is properly connected and reset the KeyWatcher. This alarm is automatically canceled by the system when
communication is restored to the box.
Return Violation
Activated when a Key Return is not valid according to the Secure Key Return feature. This is only available as an
option.
אין תוצאות